上海颐品代理英国Hawke 501/414系列接管式防爆格兰
Hawke霍克防爆格兰头(Hawke cable gland)
Hawke 501/414 Cable Glands
Hazardous Area Flameproof Exd & Increased Safety Exe
Dual Certifi ed ATEX / IECEx
Application
? Outdoor or indoor use.
? For use with non-armoured elastomer and plastic insulated cables installed in conduit.
? See technical section for installation rules and regulations.
Technical Data
? Flameproof Exd and Increased Safety Exe II 2 GD ExtD A21.
? Certifi cate No’s: baseefa06ATEX0056X and IECEx BAS 06.0013X.
? Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas
Groups IIA, IIB and IIC.
? Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1,
IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.
? Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to
IEC/EN 60529 and NEMA 4X.
? Deluge Protection to DTS01.
? Operating Temperature Range: -60°C to +100°C.
? Assembly Instruction Sheet: AI 310.
? Alternative certifi cation options available
Features
? Provides a cable retention seal onto the cables outer sheath.
? When used in Increased Safety applications, this cable gland may
be used with braided cable where the braid and the cables outer
sheath pass into the enclosure. The braid must be suitably
terminated into the enclosure.
? Provides female running coupler for cable gland or conduit entry.
? Manufactured in Brass (standard), Nickel Plated Brass,
316 Stainless Steel or Aluminium.
? Brass NPT entries are nickel plated as standard.
上海颐品代理英国Hawke SB474系列接管式防爆格兰
Hawke霍克防爆格兰头(Hawke cable gland)
Hawke SB 474 Cable Gland(防爆胶泥密封接管式防爆格兰)
SB474系列Hawke接管式防爆格兰(SB474 Hawke cable gland)
Flameproof Exd / Increased Safety Exe / Dust Extb / Dual Certified ATEX - IECEx
Application
Outdoor or indoor use. Group II Hazardous Area
For particular use with:-
a) Cable inner sheaths that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers.
b) Cables that exhibit ‘cold flow’ characteristics.
c) Enclosures for gas group IIC, under 2 litres in volume and containing an ignition source.
d) Enclosures for gas groups IIA or IIB, which are greater than 2 litres in volume and contain an ignition source.
Ordering Format [ Gland Type / Size / Male Thread / Female Thread / Material / Options ]
Example: SB 474 / C / M32 / M32 / Brass / Punch Tool No.1
Features
Provides a barrier seal between the individual insulated cores within the cable and prevents entry of the products of an explosion into the cable.
The required number of holes for the cores are punched in the seal by means of a special tool to suit the core size.
Provides female running coupler for cable gland or conduit entry.
Materials & Finishes
The SB 474 cable gland is manufactured in Brass (standard), Nickel PlatedBrass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.
Technical Data
-
Exd IIC Gb, Exe IIC Gb, Extb IIIC Db
-
Certificate No's
baseefa06ATEX0056X and IECEx BAS 06.0013X. -
Suitable for use in:
Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. -
Construction and Test Standards:
IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31. -
Ingress Protection:
IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. -
Deluge Protection to:
DTS01 -
Operating Temperature Range:
-60°C to +80°C -
Assembly Instruction Sheet:
AI 309.